import { TestBed } from '@angular/core/testing';
|
|
import { ActivatedRoute, convertToParamMap, provideRouter } from '@angular/router';
|
|
import { vi } from 'vitest';
|
|
import { BehaviorSubject, of, throwError } from 'rxjs';
|
|
import { SiteDetail } from './site-detail';
|
|
import { SitesService } from '../../../core/services/sites.service';
|
|
import { ReadingsService } from '../../../core/services/readings.service';
|
|
import { AlertsService } from '../../../core/services/alerts.service';
|
|
import { RecommendationsService } from '../../../core/services/recommendations.service';
|
|
|
|
const SITE = {
|
|
site_id: 'SITE001',
|
|
site_name: 'Site 1',
|
|
site_type: 'industriel',
|
|
location: 'Nantes',
|
|
capacity_kw: 500,
|
|
status: 'actif',
|
|
};
|
|
|
|
const CURRENT_COMPLET = {
|
|
timestamp: '2026-09-17T10:00:00Z',
|
|
site_id: 'SITE001',
|
|
site_type: 'industriel',
|
|
consumption_kw: 120,
|
|
consumption_kwh: null,
|
|
voltage_v: 230,
|
|
current_a: 12,
|
|
power_factor: 0.95,
|
|
temperature_celsius: 22,
|
|
humidity_percent: 55,
|
|
null_reasons: [] as string[],
|
|
data_quality: 'good' as const,
|
|
};
|
|
|
|
const SANS_MESURE = {
|
|
...CURRENT_COMPLET,
|
|
timestamp: null,
|
|
consumption_kw: null,
|
|
voltage_v: null,
|
|
current_a: null,
|
|
power_factor: null,
|
|
temperature_celsius: null,
|
|
humidity_percent: null,
|
|
data_quality: 'critical' as const,
|
|
};
|
|
|
|
const LECTURE = {
|
|
reading_id: 1,
|
|
site_id: 'SITE001',
|
|
timestamp: '2026-09-17T09:00:00Z',
|
|
source: 'api_history' as const,
|
|
consumption_kw: 118,
|
|
consumption_kwh: null,
|
|
consumption_euros: null,
|
|
voltage_v: 230,
|
|
current_a: 12,
|
|
power_factor: 0.95,
|
|
temperature_celsius: 22,
|
|
humidity_percent: 55,
|
|
solar_irradiance_wm2: null,
|
|
is_working_hours: true,
|
|
data_quality: 'good' as const,
|
|
null_reasons: null,
|
|
imputed_values: null,
|
|
imputation_method: null,
|
|
};
|
|
|
|
function setup(
|
|
siteId: string,
|
|
sitesMock: Partial<SitesService>,
|
|
readingsMock: Partial<ReadingsService>,
|
|
) {
|
|
const paramMap = new BehaviorSubject(convertToParamMap({ siteId }));
|
|
const getAlerts = vi.fn().mockReturnValue(of([]));
|
|
TestBed.configureTestingModule({
|
|
imports: [SiteDetail],
|
|
providers: [
|
|
provideRouter([]),
|
|
{ provide: ActivatedRoute, useValue: { paramMap } },
|
|
{ provide: SitesService, useValue: sitesMock },
|
|
{ provide: ReadingsService, useValue: readingsMock },
|
|
{ provide: AlertsService, useValue: { getAlerts } },
|
|
{
|
|
provide: RecommendationsService,
|
|
useValue: { getRecommendations: vi.fn().mockReturnValue(of([])) },
|
|
},
|
|
],
|
|
});
|
|
return { fixture: TestBed.createComponent(SiteDetail), paramMap, getAlerts };
|
|
}
|
|
|
|
describe('SiteDetail', () => {
|
|
it('charge le site, la mesure courante et son historique au démarrage', () => {
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([LECTURE])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(fixture.componentInstance.site()?.site_id).toBe('SITE001');
|
|
expect(fixture.componentInstance.current()?.consumption_kw).toBe(120);
|
|
expect(fixture.componentInstance.history().length).toBe(1);
|
|
expect(fixture.componentInstance.error()).toBeNull();
|
|
});
|
|
|
|
it("signale l'indisponibilité quand un des appels échoue", () => {
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(throwError(() => new Error('nope'))),
|
|
getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(fixture.componentInstance.error()).not.toBeNull();
|
|
expect(fixture.componentInstance.site()).toBeNull();
|
|
});
|
|
|
|
it('efface les données du site précédent quand le chargement du suivant échoue', () => {
|
|
const getSite = vi
|
|
.fn()
|
|
.mockReturnValueOnce(of(SITE))
|
|
.mockReturnValueOnce(throwError(() => new Error('404')));
|
|
const { fixture, paramMap } = setup(
|
|
'SITE001',
|
|
{ getSite, getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)) },
|
|
{ getHistory: vi.fn().mockReturnValue(of([LECTURE])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
expect(fixture.componentInstance.site()?.site_id).toBe('SITE001');
|
|
|
|
paramMap.next(convertToParamMap({ siteId: 'SITE002' }));
|
|
fixture.detectChanges();
|
|
|
|
expect(fixture.componentInstance.error()).not.toBeNull();
|
|
expect(fixture.componentInstance.site()).toBeNull();
|
|
expect(fixture.componentInstance.current()).toBeNull();
|
|
expect(fixture.componentInstance.history()).toEqual([]);
|
|
expect(fixture.nativeElement.textContent).not.toContain('Site 1');
|
|
});
|
|
|
|
it('interroge le site et sa mesure courante en parallèle', () => {
|
|
const getSite = vi.fn().mockReturnValue(of(SITE));
|
|
const getCurrent = vi.fn().mockReturnValue(of(CURRENT_COMPLET));
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{ getSite, getCurrent },
|
|
{ getHistory: vi.fn().mockReturnValue(of([])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(getSite).toHaveBeenCalledWith('SITE001');
|
|
expect(getCurrent).toHaveBeenCalledWith('SITE001');
|
|
});
|
|
|
|
it('signale la panne du capteur de consommation au lieu de tracer une jauge à zéro', () => {
|
|
const sansConsommation = {
|
|
...CURRENT_COMPLET,
|
|
consumption_kw: null,
|
|
null_reasons: ['consumption_sensor_failure'],
|
|
data_quality: 'partial' as const,
|
|
};
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(sansConsommation)),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([LECTURE])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(fixture.componentInstance.consumptionKw()).toBeNull();
|
|
expect(fixture.componentInstance.consumptionReason()).toBe('capteur de consommation en panne');
|
|
expect(fixture.nativeElement.querySelector('app-consumption-gauge')).toBeNull();
|
|
expect(fixture.nativeElement.textContent).toContain('Consommation indisponible');
|
|
});
|
|
|
|
it('trace la jauge pour une consommation nulle réellement mesurée', () => {
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of({ ...CURRENT_COMPLET, consumption_kw: 0 })),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([LECTURE])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(fixture.componentInstance.consumptionLabel()).toBe('0.0 kW');
|
|
expect(fixture.nativeElement.querySelector('app-consumption-gauge')).not.toBeNull();
|
|
expect(fixture.nativeElement.textContent).not.toContain('Consommation indisponible');
|
|
});
|
|
|
|
it('affiche explicitement les champs null avec leur raison plutôt que de les masquer', () => {
|
|
const partielle = {
|
|
...CURRENT_COMPLET,
|
|
voltage_v: null,
|
|
current_a: null,
|
|
power_factor: null,
|
|
null_reasons: ['electrical_sensor_failure'],
|
|
data_quality: 'partial' as const,
|
|
};
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(partielle)),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([LECTURE])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
const tension = fixture.componentInstance.metrics().find((m) => m.key === 'voltage_v');
|
|
expect(tension?.value).toBeNull();
|
|
expect(tension?.reason).toBe('capteur électrique en panne');
|
|
|
|
const texte = fixture.nativeElement.textContent;
|
|
expect(texte).toContain('Indisponible');
|
|
expect(texte).toContain('capteur électrique en panne');
|
|
expect(texte).toContain('Données partielles');
|
|
});
|
|
|
|
it('recharge les données quand le paramètre de route siteId change', () => {
|
|
const getSite = vi.fn().mockReturnValue(of(SITE));
|
|
const { fixture, paramMap } = setup(
|
|
'SITE001',
|
|
{ getSite, getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)) },
|
|
{ getHistory: vi.fn().mockReturnValue(of([])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
paramMap.next(convertToParamMap({ siteId: 'SITE002' }));
|
|
fixture.detectChanges();
|
|
|
|
expect(getSite).toHaveBeenCalledWith('SITE002');
|
|
});
|
|
|
|
it("ancre la fenêtre d'historique sur la dernière mesure connue plutôt que sur l'horloge", () => {
|
|
const getHistory = vi.fn().mockReturnValue(of([]));
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)),
|
|
},
|
|
{ getHistory },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(getHistory).toHaveBeenCalledWith(
|
|
'SITE001',
|
|
'2026-09-16T10:00:00.000Z',
|
|
'2026-09-17T10:00:00Z',
|
|
);
|
|
});
|
|
|
|
it('demande les recommandations du site consulté à travers ses alertes', () => {
|
|
const { fixture, getAlerts } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(CURRENT_COMPLET)),
|
|
},
|
|
{ getHistory: vi.fn().mockReturnValue(of([])) },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
fixture.detectChanges();
|
|
|
|
expect(getAlerts).toHaveBeenCalledWith({ site_id: 'SITE001' });
|
|
expect(fixture.nativeElement.querySelector('app-recommendation-list')).not.toBeNull();
|
|
expect(fixture.nativeElement.textContent).toContain('Recommandations');
|
|
expect(
|
|
fixture.nativeElement.querySelector('a[href="/recommendations?site=SITE001"]'),
|
|
).not.toBeNull();
|
|
});
|
|
|
|
it("annonce l'absence de mesure sans interroger l'historique quand timestamp est null", () => {
|
|
const getHistory = vi.fn().mockReturnValue(of([]));
|
|
const { fixture } = setup(
|
|
'SITE001',
|
|
{
|
|
getSite: vi.fn().mockReturnValue(of(SITE)),
|
|
getCurrent: vi.fn().mockReturnValue(of(SANS_MESURE)),
|
|
},
|
|
{ getHistory },
|
|
);
|
|
|
|
fixture.detectChanges();
|
|
|
|
expect(getHistory).not.toHaveBeenCalled();
|
|
expect(fixture.componentInstance.hasMeasurement()).toBe(false);
|
|
expect(fixture.nativeElement.textContent).toContain('Aucune mesure remontée pour ce site.');
|
|
});
|
|
});
|